Including:Incinerator: Structure to be specified Together with the following technical information: 1.      One pharma solid waste incinerator unit containing two combustion chambers and based on steel base with scrubbing system. 2.      3.      Capacity: Approximated 150 kg/hr. Over 10 hrs. 4.      Wastes features: ·         BULK density: 70 — 100 kg/ bm³. ·         Calorific value: 2000-3000 kcal […]
Incinerator double room with ability 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, power usage 1.2 kWH/ hour, power 3 stage with netral, cooling water sprinkler capacity 5L/ minute, finished with refractory (insulation, castable, ceramic covering) and PLC SUPPLY, INSTALLATION As Well As COMMISSIONING OF WASTE […]
MAINTENANCE CONTAINER BE FINISHED WITH RESTRICTED TRAINING – COMPLIES WITH EURO/ OR US-EPA DISCHARGE REQUIREMENTS – CAPABILITY TO MELT SQUANDERED LUBRICANTS (POL) – HANDLE ORGANIC SOLIDS (TO CONSIST OF RMW) – DEPLOYABLE – MOBILE – 24 HUMANS RESOURCES OF CONTINUOUS USE – AUTOMATIC LOADING SYSTEM – AUTOMATED ASH REMOVAL SYSTEM – GAS SCRUBBING SYSTEM – […]
PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM GAS SCRUBBING SYSTEM […]
Prerequisites of Burner 1. Must have groundwork, Incineration, Scrubber measures to melt waste entirely and waste gas have to be non-polluted 2. Strong steel, heat resistant coating, stainless steel cover, painted tubular steel frame, 2-blowers, axial vane, appropriate drum (S/S, thick) for the burner should be provided. 3. Approximate. 20 to 25 Kg per set […]
The household pet cremation equipment humanized design with movable platform, small area covers for modern-day pet cremation local business owner throughout the world. HICLOVER is growing brand for environmental protection field, and also market show most of Africa, Middle East, Southeast Asia countries as well as part of North America, Europe area. We a re […]
Opacity is the amount to which the exhaust gases reduce the transmission of light and obscure the sight of any sort of object in the background. It’s expressed as a portion representing the degree to which a things watched with the gases is coated. Though not an emission standard, opacity gives a indication of the […]
More smoke in addition to other pollutants are launched right into the air throughout the ‘start-up’ also as ‘trendy ’ phases of the burn cycle than throughout the ‘full melt stage’ when high temperatures are maintained. Low temperature level smoldering fires must be avoided. Melt just dry feedstock and occasionally add additional waste to the […]
Polaris Power saving Information: With the significant use the medical care industry as well as the advancement of clinical non invasive products, clinical waste production is growing rapidly. The most recent data show that there were 261, in the city to the area strong waste air pollution prevention details, just those 261 cities this year, […]
The middle-class Foxboro class in North Salt Lake City, Utah, is, in many procedures, an ideal place for young households — — brand-new, modest, likewise sized houses on rather small wonderful deals, nearby neighbors attached by walkways in addition to streetlights, tons of playmates for all the kids. And also Mormon neighborhoods have great deals […]
Double Combustion Chamber Waste Incinerator Mounted in ISO 20′ ′ or 40 ′ Container before leave Factory. Free Installation The incinerator layout with primary burning chamber, additional burning space ( blog post burning) as well as dry scrubber optional. This style will decrease black smoke, shed completely and Environmentally Friendly. Mobile Incinerator The incinerator placed […]
use in the hospital for burning hazardous waste as well as chimicals, minimal Skill 300 per hr. I’ll be marketing to my client? . Below is the info I was given and nothing else. The hospital burner for use in the professional waste as called for by worldwide ecological management. Minimum 300 Kg capacity/hr, Gas […]
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire,  mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class ,  facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste,  whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the  end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to  process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and  installation of the TS150 PLC Incinerator and am in  need of technical assistance? 6. What are the most commonly needed repair parts?a)   Waste Auto Loading Ram Hopper  b)   Standard Tools (What the tools are there?, Please figure out) c)   Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d)   Commissioning and Training  e)   Support wires, clamp and bracket as chimney is 33 m height              HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)   Waste Incinerator RFQ(Request for Quotation) http://www.covid19.africa-incinerator.com/ad/rfq/   EStore for Waste Incinerators http://www.haiwos.com   2022-06-24 […]
100 Kg/Hr Bio-Medical Waste Incinerator, wet scrubber/spary tower optional. 2 combustion chambers, italy burner, APO function,    PLC auto control system incinerator   Incinerator Items/Model HICLOVER TS100(PLC)   Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 200kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V […]
Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries •Autopsy centers Other Sources of Healthcare Wastes •Physicians’ offices •Dental clinics •Chiropractors •Psychiatric hospitals •Cosmetic piercing and tattooing •Institutions for disabled persons •Funeral services •Home healthcare •Define healthcare waste •Describe sources and examples of healthcare waste •Describe general characteristics of healthcare waste •Identify where wastes are generated in your facility •Categorize the wastes into two general categories based on whether or not they pose a risk •Describe general characteristics of the wastes Definition of Healthcare Waste What is healthcare waste? – Total waste stream from major healthcare establishments and from minor scattered healthcare activities General Types of Healthcare Waste Healthcare waste can be –Non-hazardous general wastes comparable to domestic waste (75-90% of healthcare waste in a health facility) –Potentially hazardous waste or waste that is associated with some health risks (10-25% of healthcare waste in a health facility) Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries […]
4. The Service provider shall offer in addition to fully comply with all needs from the associated authority during design stage, layout authorization, assessment and after evaluation, handing over of the system bundle whether it’s clearly shown or otherwise yet considered needed for successful conclusion in addition to contentment to the authority. The Contractor must […]
Continuous Feed An incineration process that is in a constant shed cycle. A constant feed Incinerator burner works without interruption throughout the operating hours at the center by having waste continuously added to the key burn chamber. Establish Feed Incinerator An incineration process that is not in a constant or mass burning cycle. A set […]
If burning and incineration is used, the devices picked need to be made as well as sized to match the waste produced, minimize fire danger and also result in the entire burning of the waste. Despite having better waste reduction measures in place there will certainly be waste created. Waste by its nature is normally […]
[China] Solid Waste Environmental online waste incineration sectors advancement momentum is tough, and the brightest of resources chasing also appear numerous times in the in 2014 the rate of handling price diving, sector increased concerns regarding the vicious competitors. “Thirteen Five” throughout garbage building and construction market investment space at 1000 billion yuan; the growing […]
Double Combustion Chamber All waste burner design with dual combustion chamber. High Temperature, Smoke Remedy , No black smoke, Eco-friendly. Containerized Mobile Incinerator The incinerator mounted in ISO Container before depart mill, free-installation, no incineration residence develop building and construction, movable by truck. Family Pet Dog&Cat Cremation Unique style with movable platform, combustion chamber material […]
Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg Loading Manual, Batch Load De Ashing Automatic or Manual batch de ashing The incinerator must avoid the release of black smoke and fine dust during the loading Primary chamber capacity […]
a. 2.5 metric loads daily health care waste burner b. 1.5 metric heaps daily healthcare waste burner c. 300 kg daily medical care waste burner Our preferred technology is double-chamber incineration, but if you suggest a different modern technology, that is acceptable. We request information on the following for every of the above demands: 1. […]
daily, called for variety of devices -10 to 25 numbers Installing different sort of waste Tracking systems ideally Incineration as well as others for the state Jammu & & Kashmir India maker and also retailer of various Incinerator and other items. Please be kept in mind that we are a leading Bangladeshi company house dealing […]
Incinerator Items/Model HICLOVER YD30(PLC)     Burn Rate (Average) 15kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 360L(0.36M3) Internal Dimensions 100x60x60cm Secondary Chamber 200L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V  Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature Thermometer […]
shed between 5000-10000 pound per hour.Mostly waste from petroleum storage tanks. Building and construction, installment and 6 months upkeep expense including specifications.CMSD for Double Chamber Rotating Klin Kind Incinerator (1st Chamber temperatur less than 850 level centrigrade & & 2nd Chamber Temperature Level less than 1200 c with exhaust pipeline 100 meter long with discharge […]
Aeration gate valve,Burner fuel pump,Circuit board (LM44.255C2BT), controller for Riello FS10 gas burner,Emergency push button, https://www.haiwos.com/#!/Incinerator-Spare-Parts/c/122963267  https://www.haiwos.com/#!/Waste-Incinerators/c/122950677  Fire proof flange gasket,Flexible Conduit,Fuel filter,Ignition transformer, Incinerator Automatic Protection Operator(APO) Controller, Nut for Temperature Thermocouple-Temperature  Probe,PLC auto control incinerator, Solenoid,Stainless steel tension wire,Temperature display controller K type, Temperature display controller S type
Local waste incinerator amounts and capacities will be made for 24-hour 7-day-a-week continuous operation. Incinerators shall be capable of processing both moist and also dry material and also working on diesel fuel, JP-8 gas, or waste oil; visit Plumbing for gasoline storage system needs. The complying with will be provided as a minimum: Strengthened concrete […]
1) Power Supply: ( a) Keys Supply: ( I) Solitary Phase supply; 220– 240V, 50Hz ( ii) Three Stage supply; 380– 415V, 50Hz ( iii) The power supply electric outlet (sockets) for single phase distribution system in the hospital is three hooks and also complies with BS1363. (b) Change: ( I) Mains change is an […]
https://www.haiwos.com/#!/Model-TS10-Incinerator-with-wet-scrubber-Spray-Tower-and-Defogging-Tower/p/472484002/category=0  Incinerator Items/Model HICLOVER TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil Consumption (kg/hour) 6 N.Gas Consumption (m3n/hour) *** Temperature Monitor Yes Temperature Thermometer […]
Incinerator but the dimension of chamber > > 2000 x >> 1200 mm. Plan for burn FLUID Waste +/- 20 liter/hr. C: The amount of set can we place in everyday basis daily. Sustained by Heavy OIL Burner.waste disposal incinerator, with the ability of coping with both wet and totally dry rubbish. That include home […]
1. I. Dimension of the Incinerator 4,410 W x 3,037 L x 4,836 H mm II. Ability of the Incinerator Medical waste 50 kg/hr. Set feeding (low level calorie value: 4,000 5,000 kcal/kg) III. Utility Utility problem for the incineration devices operating is the adhering to. 1) Gas: Light oil or Kerosene 2) Electric Power […]
  –          150 KG/HR –          Compliant with EU principles, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and upkeep –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for harmful waste containing halogenated organic substances with content of chlorine or its compounds.
Demands and specs for the process of supply, installation, operation and make sure the three incinerators for burning and incineration of medications and also harmful compounds for customizeds branch Free 3 years warranty for incinerators from shipment day. In addition of complimentary added components ensure letter needs to be valid for 10 years from the […]
We’ve got a 70 bed medical facility in namibia. There’s a possibility of getting customers from several other regional doctors.
incineration Heater for burning patalogical (such as human blood or tissue ) as west The weight of this west stuff is 700 kg per month and we need an isolated heating system Without fume in addition to any sort of damaging gasoline . INCINERATOR SPECIFICATION # Summary Specification 1 Burning Capacity – – 400 kg/time […]
51. No    Attributes $_pecific tions 2.     Load capacity    300 – 4∞Kg (maximum) Warranty of one year from the date of commissioning. Separate   Annual    Maintenance    Contract   will be drawn with the provider at a later stage. bidding document 13.     Civil    works,    installation    and Onsite  demonstrationjperformance  evaluation and  adequate training of staff on the use […]
Automatic filling and refilling with capacity of 10 to 12 bunches per day working with gasoline therapy methods and gas fuel and also ought to obey the European Standards.the Federal Government Healthcare Facility for Medical Waste Incinerator with the adhering to Specifications. They are having fundamental wastes such as cells, plastic bottles etc, wastes originating […]
* A switch breaker for every engine (ventilators and also burners). Natural rubber, synthetic rubber, polyurethane sheet, and cumbersome movies, solids and also * The insulation of the burning chamber should be composed of refractory bricks, using a high content of aluminum and also insulates bricks in order to guarantee a minimum temperature on the […]
ADVANCED PYROLYTIC MEDICAL WASTE BURNER 1. NB.; Civil functions as well as any various other relevant solutions for the installment as well as training of drivers need to be contained in the burner’s rate. Requirements for the shelter of the burner: House of the incinerator comprehensive in deal (your home must have toilet as well […]
it’s additionally really critical for us to understand whether the device is qualified to manage cytotoxic waste as well as the characteristics in addition to disposal of treatment deposits. Moreover, operational requirements in regards to energy and also gas consumption, along with particularly the off-gas treatment system employed, birth substantial value, as meeting the requirements […]
50 kg/  hour  capacity incinerators ·        Burning Rate: 50kos/hr ·        Feed Capacity:  150kqs ·        Main Combustion  Chamber:  900 liters ·        Secondary  Combustion  Chamber:  300 liters ·        Mix Combustion  Chamber:  Yes ·        Smoke Filter Chamber:  Yes ·        Feed Mode: Manual ·        Power: 0.7Kw ·        Fuel Type: Diesel Oil/ Natural Gas/LPG ·        Internal Dimensions:  120 x 90 […]
Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal units and flue gas treatment systems, with the following details: Hourly capacity of the system:           from 250 up to 500 Kgs/ hour Duration of operation:                        from 14 up to 18 hrs/ day Fuel type to be used:                         Diesel or other […]
Incinerator but the dimension of chamber > 2000 x >> 1200 mm. Prepare for melt FLUID Waste +/- 20 liter/hr. The chamber of the incinerator should be able to hold about 200 – – 250 kg of waste in an offered time. edical Waste Incinerators. The mobile system is our concern then the fixed systems. […]
common daily massacre involves 120 pigs. The Condemned item as well as also byproducts from the abattoir for Entry is around 1000 kgs.daily – – – – Heater capacity of damage of 350 kg/hour, calorific well worth of waste will surely be 13-25 MJ/kg [3,500 kcal/kg] and also ideal cozy ability 1,225,000 kcal/hr. – – […]