Month: November 2022

Item Specification Model YD-30C Main Product List Main Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(Update to Stainless Steel, free cost) Italy gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Automatic PLC controller incinerator plant with […]
In a simple design with a metal steel drum electric. including: Ancillaries High temperature painting for several of the incinerator. A combustion chamber with fireplace using a filter to retain ashes; Weight    1850kgs Supply of incinerator model PDR-18 with: ·        Ability 100 kg/hr of waste containing up to 85% moisture ?      With 2 diesel pipelines, […]
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(Update to […]
hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center. –    Materials (wastes) that need to be stabilized before buried –    Buried materials The Incinerator Plant is output wastes incineration from various petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and produced […]
Model YD-30 Mobile Type Picture   Burning Rate Average 30 kgs/hour Feed Capacity Average 60 kgs/feeding Chamber Main Body Stainless Steel Mobile Function With Wheel and Brake Main Combustion Chamber 280 Liters Secondary Combustion Chamber 150 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 1.5 Kw Fuel Type Diesel Oil Burner Italy […]
BURNING RATE: -100-150kgs per hour MINIMUM OPERATING TEMPERATURE: 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE: 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY: COMPULSORY DENSITY INSULATION: 50 mm high Refractory capacity: min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME: MAXIMUM 3HRS FUEL TYPE: FUEL OIL ( […]
Model A600, crematorium manufacturers Internal Dimensions 130 x 70 x 65cm Suit for Animal Cat – yes Dog – yes Pig – no Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 Components […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use   Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
medical waste diesel incinerator Burning Rate:47.5–50kg/hour 3) Compliance with applicable Haitian standards and regulations. Operational characteristics Refractory Casting:Minimum 65mm 7) Mounted on a secure foundation, as per example below.
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour […]
Incinerate: medical waste and general waste Capability to burn waste: ·         Use: For medications ·         With Chassis to be Mounted in truck/lorry ·         May have a primary and secondary combustion chamber ·         Must have a dilution chamber ·         Ability: 100 Kgs per hour
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Typical 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display […]
General specifications of a 100 kg/hr incinerator No. Description Parameter value     model   HICLOVER YD100 1 Machine working mode Oil + Power Oil + Power 2 Voltage 220V C 3 phase or 1 phase 220V 1P 3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners 6 Incineration rate 100 kg/hr […]
1. GENERAL SPECIFICATIONS: The incinerator for medical waste needs to be designated for the destruction of all kinds of waste produced by the Center for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h). Avoid development of black smoke and dust formation tine loading of waste; . Afterburner ? 1 […]
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core  HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.covid19.africa-incinerator.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   smart
Toxic and Harmful wastes, Combustion supporting materials Oil Industrial wastes 35.64 small scale medical waste incinerator Prerequisites <78dB Index of let smoke and waste gas Medical Incinerator, 24 kg/hr including panel board, controls and accessories Guide Medical Incinerator, 24 kg/hr 200 beds Input Fashion Domestic garbage Chimney 0.016 800-10000C 1000-12000C Burning efficiency Gas Medical Incinerator, […]
Items/Model TS50M Picture   Burn Rate Typical 50 kg/hour Feed Capacity Typical 50-150 per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 450L Internal Dimensions 75x75x80cm Secondary Chamber 225L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Typical 13.3 Gas Consumption (N.G, m3n/Hour) Typical 16 Gas Consumption […]
Waste type: health care waste It is carried from the floor level on a considerable steel support frame.  Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or higher strength castable. The primary combustion chamber must ensure minimum exit temp is not less than 850? C. […]
Design for Pets Cremation Business Movable platform & Auto. Independent Position for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Model A1500 Picture Burning Rate Average 150 kgs/hour Feed Capacity Average 350 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke […]
Average 30kgs per hour ***Main chamber(200Liters) *** Secondary chamber *** Mix combustion chamber *** Stainless Steel chimney(1meter) *** Italy made oil burner(2sets) *** Dry Scrubber *** Weight 1.7T(can reduce to 1.0Ton) Main Spare Parts(Standard for incinerator, and price Comprise already): *** 2 sets Italy Oil Burner *** 2sets Temperature Probe *** 1 set Control Case […]
d) A smoke density meter/recorder should be provided. G) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16 hours. – Manual technical monitoring is shipped with the hardware together with all explanations of failures and resolutions B) The […]
1. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt blown Production Line   A.)Optional Ability: 1600mm Efficiency: 95-97percent FOB Term Cost: USD per set Price Valid: 5days. Ave.60 Days prepared for shipping. In stock Price: USD per set     B.)Optional […]
9. Metal fuel tank from black steel (capacity not less than 2500 litres) and will be installed in the incinerator Room. The tank shall be supplied with all necessary fittings such as fill, vent, drain and overflow line, level indication and accessibility for inspection and maintenance. Level switches shall be provided for these services. – […]
the Whole carcass of animals ( Horses, Cows, air retention for at least 2 seconds at a temperature of less than 850C, the combustion C to – 15 0C laboratory incinerator Temperature and 5% – 95 percent – of moisture conditions. Which are managed remotely by the operator. ? Fully mobile – mounted on wheeled […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.covid19.africa-incinerator.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
● Willing to burn 25-30kg per hour 2 sec. 1000×1670 -Stainless steel stack Width (mm) -Automatic control and temprature 790 ● Need more than 15amp 220- 250V power ·         General wastes produced on a daily basis  include paper, plastic, organic materials, boxes, plastic containers, leaves, etc; ·         Total waste produced daily: 10-12 tonnes; ·         Hours […]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L […]
? Refractory concrete : OA burner of lighting which the use is restricted to the ignition of waste. OA sheath of evacuation of the gases burnt. ? Refractory concrete : OA apparatus of air ducts of cooling of waste gases, OThe insulation of the combustion chamber ought to be composed of refractory bricks, using a […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Expired Drugs Liquid ?     Each unit to be provided with recommended spare parts Rags, absorbents, cardboard, oil and fuel filters, air filters are not considered as hazardous materials Electronic Waste Used motor oils or mineral oils unfit for their originally intended use. Mainly motor/gear box oil (approx. 80%) infected by a  mixture of white […]
incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator Items/Model TS100 Burn Rate Typical 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Yes Temperature Protection […]
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono Stage l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg   焊接机参数: Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono Stage l Compressed Air Link: 0.5 to 0.7Mpa l Dimension(L*W*H): 900mm*650mm*1380mm l Net weight: approx. 50kg   KN95口罩机参数: N95 Mask Machine l Capacity: […]
Burring Ability 100 / 200 KG/ hr    Please write your offer here 2.       Ability: to cremate (carrion and spoils) 350-400kg/hour 4.       Temperature: 900-1350? C 5.       Operation temperature: -30~40? C 6.       Incinerator pounds: 1800-2000 kg 7.       Volume: 0.70-0.80m/cube 8.       Exterior dimension: 1.4-1.6*1.0-1.15m (L*W)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected]  Face Mask Machine for Coronavirus Disease COVID-19 Ø Overall Dimension:900mm*650mm*1380mm 2020-04-03 Ø Net Weight: about 1000kg Ultrasonic Welding Machine   Technical Parameter: Ø Capacity: 5 to 10 pcs/Min(Depending on Raw material condition) Ø Power source: 8.5KW (220V/50Hz Monophase) Ø Compressed Air link: 0.5 to 0.7Mpa Technical Parameter: Ø Function: To generate non woven face […]
Hazardous medical waste: Clinical and related waste, arising from medical, nursing or comparable practices and waste 2. The unit should function wit. No fuel and use only 120V or 220V electricity for the blowers. grease, and paraffin based xpired medicines. Expired and/or polluted fod: Spoiled fresh food or unusable MRE’s (Meal Ready for Eat – […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
HICLOVER – Medical Environmental  Model YD-30 (Custom Edition) Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption […]
Waste calorific value : 4000KCAL/KG INSULATION ·???????? Control panel — automatic operation Secondary Chamber : 2 Seconds @ 850degrees C Calcium Silicate ·???????? High capacity secondary combustion chamber with home time not less than 2 minutes @ p 850°C ·???????? Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
Secondary Chamber    Temperature *    1100 — 1300 deg. C Dimensional Sketch, Operation & Installation Manuals.     Required Away — Gas System    Required Thickness    25 ” minimum Delivery    Karachi Sea Port – Pakistan The details of Components of incinerator is as follows: System Status & Alarms    Required for all vital parameters. Media    Slightly acidic Heat Insulation   […]
Items/Model TS30(PLC) Picture   Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Car Control and Display Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) […]
Ø  FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw Ø  NUMBER OF SECONDARY BURNERS & RATING: 2 @ 400kw; ELECTRICAL SUPPLY 230V 60Hz Ø  BIN TIPPER, MONITORING SYSTEM, CLEANING SYSTEM Ø  GAS CLEANING AND GAS MONITORING.MSW1000 General Medical Waste Incinerators burn rate up to 100kg/hr The following should be signaling in […]
Model WS-35 Picture Burning Rate Average 35 kgs/hour Feed Capacity Average 80 kgs Main Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Liters Third Combustion Chamber 200 Liters Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Fuel Type Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption […]
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Typical 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature […]
the incinerator can be used to dispose  Medical waste IV, used needles, used syringes, scalpels, used dressing material,personal protective equipments such as dress, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mixture of medical and hazardous wastes. The healthcare wastes include (but aren’t limited to) materials […]
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Gas Diesel oil Burner Italy […]