1.
9. Steel gas storage tank from black steel (capability less than 2500 litres) and will be installed at the incinerator Space. The container will be provided with all needed installations consisting of fill, vent, drain as well as overflow line, level sign and also access for evaluation and also maintenance. Degree switches over will be offered for the complying with options.
(a) Reduced level alarm system.
– – Does it allow to deal with drug or waste consisting of glass (whatever color: clear or colored white) without tripping surges?
4. The incinerator covering will be produced from SS/MS plate of proper thickness (minimum 5mm) as well as painted on the surface with heat resistant aluminum paint appropriate to hold up against temp.of 250 dc with correct surface preparation. Refractory liner of the warm duct will be done with refractory castable (minimal 45mm thick)& & insulation castable( minimal 80mm thick).
5. There’ll be a separate burner each for the main & & second room. The hot input capacity of each burner shall suffice to increase the temp.in the primary & & secondary chambers as 800+/- 50dc and 1050+/ -50 dc specifically within optimum of 60 mins before lose billing. The heaters shall have automatic shifting off/on control to remain clear of the changes of temperature levels beyond the called for temp.range.
The double room incinerator shall ideally be made. Air supply in the primary and secondary chamber shall be controlled in between 30% -80% as well as 170% -120% of stoichiometric amount specifically. Circulation meter/suitable circulation measurement tool shall be provided on the key and second air ducting. The combustion air shall be supplied with a separate forced draft fan accounting for the atmosphere supplied with burners. Provision shall be made in the primary chamber to estimate the water column pressure.
2.
( c) Reduced degree beginning of pump.
( b) High degree alarm system.
– – The efficacy of process chemicals (after neutralization and also cleansing: solids as well as liquids).
– – The capacity of the liquid waste treatment (blood, urine discolored, other body fluids contaminated, no matter what amount product packaging?
( d) High degree stop of transfer pump
10. An all set constructed produced space shall be provided for real estate the incinerator. The area will definitely be created in such a way that vacuum is offered on all sides and heat radiation maintained minimum as well as offering the operators a simple convenient environment as well as ventilation. The materials will be sufficient structural depth of moderate steel angles covered with metal primer and epoxy repaint to hold up against sea rust.
3. Clinical incinerator maker The refractory lining of the room shall be strong sufficient to keep minimal temperature of 1000dc in the primary room and also 1200 dc in the secondary chamber.
6. Incinerator shall have visuals or computer system recording tool which shall instantly and also continuously screen as well as document dates, time of day, set consecutive number, Carbon monoxide, Co2, O2 in gaseous exhaust will also be gauged daily.