Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor Digital Display Temperature Protection Yes […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor […]
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3n/hour) Average 53(NG) Temperature Monitor Digital […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration […]
Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to energy plants cost Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital Display Temperature Protection Yes […]
Item Specification Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower) Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture Feed Capacity 78 Liters for primary chamber Burning Rate Average 30 kgs per hour Burning Time per Feed 0.5 hour Voltage 220V Power 0.5Kw Fuel Diesel oil Burner Diesel Oil Burner, 2 sets Feed Mode Manual Fuel consumption (Oil) Average 8 Kgs/Hour External Dimensions 90 x 90 x […]
Items/Model TS75 Picture Principle Solid Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Display Temperature […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf. The […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall […]
Model A1500(Movable platform & Auto. Door) Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 34 kg/hour […]
Items/Model TS1000 Picture Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
Medical Waste Incinerator Capacity: average 50-100 kgs per hour Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. […]
The equipment proposed shall be an incinerator specialised for Medical Wastes. Medical waste may consist of discarded materials or equipment contaminated with blood and its derivatives, other body fluids or excreta from infected patients with hazardous communicable, contaminated waste from patients known to have blood-borne infections undergoing haemodialysis (e.g dialysis equipment such as tubing and […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Our products ensure […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 1.0 Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) *** Gas Consumption […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage […]
Top Openning Door Waste Incinerators Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L Smoke Filter Chamber Dry Scrubber Dry […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or 3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or 3 sections) ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Model YD-30 Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption (Natural Gas) […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. ● Double Combustion Chambers All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. ● Containerized Mobile Incinerators The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. ● Family Pets Dog&Cat Cremation Special design with movable platform, […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS20(PLC) Picture Principle Medical Waste Incineration Burn Rate Average 20 kg/hour Feed Capacity Average 40kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 210L Internal Dimensions 65x65x50cm Secondary Chamber 110L Smoke Filter Wet Scrubber (Water Spary tower) Feed Mode Manual Voltage 380V Power 5Kw Oil Consumption (kg/hour) 7.8–16.3 Gas Consumption […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Capacity: Average 300 kgs per hour Model YD–300 Picture Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs/feeding Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Wet Scrubber System(3 Section Type) Feed Mode Manual Voltage 380V Power 12.0 Kw Fuel Type […]
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Item Serie No. Part Name Packing List 1# Incinerator Mainbody 2# Oil Tank(Deposit) 3# Oil Tank(Daily) 4# Chimney(Vertical,High Temperature) 5# Chimney(Horizontal,High Temperature) 6# Wet Scrubber 7# Chimney(S shape) 8# Chimney(Below) 9# Chimney(Top) Hospital Incinerators for Medical […]
Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious (“red bag”) medical wastes as well as non-infectious, general housekeeping wastes. Items/Model TS30(PLC) Picture Burn Rate […]
HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration General Waste Incinerator For MSW Mobile Incinerator(Optional) Small-Middle scale, mobile function by 1. )Wheel 2.)DC-Power Trolley 3.)Trailer 4.)Containerized Wet Scrubber […]
Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.covid19.africa-incinerator.com/ Email: sales@covid19.africa-incinerator.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. 2020-07-21
Smallest Waste Incinerator for PPE waste face mask glove waste Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney ave 10kgs per hour, 100kgs per day(10hr/day working) Equipment Technical Specifications Model YD-10 Picture Feed Capacity Average 20 kgs per feeding Burning Rate Average 10 kgs per hour Burning Time […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]
having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust. Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. […]
HS Code for waste incinerator 84178050 Item Specification Model TS100 PLC Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 units Oil Tank (if oil fuel): 200Liters […]
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment(Poultry and dead fish Incinerator Machine) Burn Rate Average 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 970L Internal Dimensions 120x90x90cm Secondary Chamber 480L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V-240V Power 0.7Kw […]
Model YD-30M Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Control Case Stainless Steel Chimney: 1.5 Meter Italy oil/gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Video material: https://twitter.com/i/status/1279030799182905345 Model YD-30M Picture Burning Rate average 20 kgs/hour Feed Capacity average 40 kgs/feeding Paimary Combustion Chamber 200 Liters Secondary […]
Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Items/Model TS30(PLC) Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L […]
Small Waste Incinerator, 10kgs per hour capacity, PLC control Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas Consumption (m3/hour) average […]
Pre-assembled, containerized type Incinerator Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor […]
30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan Machine Working mode Oil or Gas + Power Voltage 220V Oil consumption (lit/hour) Average 13.3lit/hour/chamber Gas consumption (NG) (m3/hour) 16.0 (m3/hour) (NG) Gas consumption (LPG) (m3/hour) 11.7 (m3/hour) (LPG) Burning rate Average 30kg/hour Feed mode Manual Primary Combustion chamber 360 Liters Secondary Combustion […]
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30 Picture Burning Rate average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel […]
Waste Incineration HICLOVER Model TS75 Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average 16.9 Gas Consumption (m3/hour) *** […]
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas […]